The HM1005 is a multi-function oscilloscope loaded with features such as true 3 Channel operation. a genuine second time base, and even a separate second trigger facility. Up to 6 traces can be displayed for evaluating waveform relationships by using the alternating time base mode and all three input channels. In this configuration, the normal signal is displayed together with the expanded signal section. The second trigger facility, with its own separate slope and level control, provides for the stable viewing of normally troublesome asynchronous signal components. The main time base trigger circuit is designed to provide reliavle triggering to greater than 130MHz, at signal levels as low as 1 division. a user-selectable x10 magnifier extends the maximum sweep range to 5ns/division. An active TV Sync Separator extracts clean field and line sync. pulses to ensure a gihg degree of display stability when viewing composite video signals.
The built-in delay line permits viewing of the trigger edge at all times. The over-scan feature indicates if any part of the trace passes beyond the vertical limits of the CRT screen. An analof Y-ourput, switchable to Channel Ⅰ or Ⅱ, allows further external processing of the signal. Another new feature on the HM1005 is the wasy-to-read 3 digit LED delay time multiplier for accurate measurements.
As is the case with several HAMEG oscilloscopes, the HM1005 also has a built-in switchable 1kHz/1MHz Calibrator with a sharp <5ns risetime output. This feature is necessary in high bandwidth oscilloscopes so that the probes can be correctly matched and compensated to ensure faithful reproduction of the input signals. This is especially true when viewing pulses and other high frequency signals. The calibrator is also useful for performing checks of the instrument's transient response characteristics from probe tip to CRT screen.
The HM1005 offers the right combination or triggering control, frequency response and time base versatility, to facilitate measurements in every environment from the laboratory to field service. It is yet another example of HAMEG's dedications to engineering excellence.
Key Features
• 100MHz Oscilloscope
• 3 Channels
• Time Delay Base
• 2 Conventional Channels
⊙ With Calibrated Gains of 5MV/dic - 5V/div
• 1 Channel
⊙ With Variable Gain
• Time Base 0.05 usec/div - 1 sec/ div
Spec Comparison
| HM1004 | HM1005 |
CHANNELS | 2 | 3 |
AUTOSET / SETUP MEMORIES | YES / 6 | NO / NO |
ANALOG BANDWIDTH (-3dB) | DC - 100 MHz | DC - 100 MHz |
INPUT SENSITIVITY | 5 mV/div. | 5 and 50 mV/div. |
MAGNIFIED (BANDWIDTH -3dB) | 1 mV/div. (DC - 10 MHz) | 1 mV/div. (DC - 10 MHz) |
Y-DELAY LINE | YES / 90 ns | YES / 90 ns |
TRIGGERING | DC - 150 MHz | DC - 130 MHz |
TRIGGER DELAY / 2nd TIMEBASE | YES / NO | NO / YES |
TIMEBASE (ANALOG) | 0.5 s/div. - 50 ns/div. - | 1 s/div. - 50 ns/div. - |
MAGNIFIED | up to 5 ns/div. - | up to 5 ns/div. - |
TIMEBASE (DIGITAL) | N/A | N/A |
MAGNIFIED | N/A | N/A |
DIGITAL SAMPLING RATE | N/A | N/A |
A/D CONVERTER / RESOLUTION | N/A | N/A |
STORAGE MEMORY | N/A | N/A |
REFERENCE STORAGE MEMORY | N/A | N/A |
PRETRIGGER | N/A | N/A |
ROLL MODE | N/A | N/A |
SINGLE EVENT CAPTURE (analog / digital) | NO | YES / NO |
XY MODE (analog / digital) | YES / NO | YES / NO |
DOT JOINER | N/A | N/A |
EXTERNAL CLOCK INPUT | N/A | N/A |
COMPONENT TESTER | YES | NO |
CALIBRATOR 0.2V / 2V | YES | YES |
Y OUTPUT / SAWTOOTH OUTPUT | NO / NO | YES / YES |
BLANKING INPUT | NO | YES |
ACCELERATING VOLTAGE | 14 kV | 14 kV |
OPTION : Readout AND Cursors | YES | NO |
OPTION : RS-232 for REMOTE CONTROL | YES | NO |
HAMEG INTERFACE | NO | NO |
General Information
Cathode-ray tube | D14-372 P43/123, intern. gratic., 8 x 10 div. |
Acceleration voltage | approx. 14kV |
Trace rotation | adjustable on front panel |
Graticule illumination | 3 steps |
Z modulatiion | TTL level, pos. going. 3-digit delay position display. Calibrator 1 kHz/1 MHz, 0.2V (t < 5ns), and 2V ±1% |
Line voltage | 110, 125, 220, 240V~±10% |
Power consumption | 44 Watt, 50/60Hz |
Protective system | Safety classⅠ(IEC348) |
Colour | techno-brown |
Cabinet (W x H x D) | 285 mm x 145 mm x 380 mm / Lockable tilt-baii/handle |
Ordering Information
Warranty
• 1 YR
Contents
• HM1005 Oscilloscope
• 10:1 Wideband Probe x 2
• Line Cord
※ 자세한 사항은 'DataSheet'나 'Quick Start Guide'를 참조해 주세요.
품명 및 모델명 | 상품상세 참조 | 제조국 또는 원산지 | 상품상세 참조 |
---|---|---|---|
제조자, 수입품의 경우 수입자를 함께 표기 | 상품상세 참조 | A/S 책임자와 전화번호 또는 소비자상담 관련 전화번호 | 상품상세 참조 |
법에 의한 인증·허가 등을 받았음을 확인할 수 있는 경우 그에 대한 사항 | 상품상세 참조 |
- 배송비 : 기본배송료는 3,000원 (제주도 및 일부 도서산간 지역은 배송비가 추가됩니다.)
\200,000원 이상 구매시 무료배송
- 오후 5시 이전 주문시 통상적으로 당일 발송
- 제품 품절인 경우가 있기 때문에 납기일 확인 후 주문 부탁드립니다.
- 배송예정일은 주문시점(주문순서)에 따른 유동성이 발생하므로 평균 배송일과는 차이가 발생할 수 있습니다.
- 본 상품의 배송 가능일은 결제완료 된 날로부터 2~3 영업일입니다. 배송 가능일이란 본 상품을 주문 하신 고객님들께 상품 배송이 가능한 기간을 의미합니다.
교환 & 반품안내
- 특수 제품, 주문 제품 등의 경우, 그 특성상 주문이 접수된 후 취소 및 환불이 불가합니다. 주문 전 충분히 상담하신 후 구매해 주세요.
(특수 제품이란, 보유제품이 아닌 주문 후 생산하며 출고하는 제품을 말합니다.)
- 제품 특성상 주문이 접수된 후 단순 변심에 의한 취소 및 환불은 당일에 한해 가능합니다. (취소및 환불 접수전 반드시 고객센터를 통해 연락바랍니다.)
- 전자 제품 특성상 제품포장 개봉 후에는 교환 및 환불이 불가능합니다. (제품 하자 제외)
- 모든 교환·반품은 수령 후 7일 이내 접수되어야 하며, 접수 전에 고객센터로 문의해 주셔야 진행이 가능합니다.
- 미개봉 제품의 경우, 받으신 날로부터 7일 이내 접수하시면 교환이 가능합니다.
- 개봉하신 제품은 7일 이내라도 교환이 불가합니다.(제품 하자 제외)
- 배송된 날로부터 7일이 지나면 어떤 교환·반품도 불가하므로 받으시면 제품 상태를 꼭 확인해 주세요. (제품 하자 포함)
- 소비자 변심에 의한 교환은 왕복 운임을 부담하셔야 합니다.
환불안내
- 상품 청약철회 가능기간은 상품 수령일로 부터 7일 이내 입니다.
- 주문 제품, 특수 제품의 경우 교환/반품이 불가합니다.
- 주문 전 충분한 상담을 하신 후, 신중히 구매해 주세요.
- 환불신청시 왕복 운송료를 부담하셔야 합니다.
AS안내
소비자분쟁해결 기준(공정거래위원회 고시)에 따라 피해를 보상받을 수 있습니다.
:: A/S 처리 문의 ::
전화 : 02) 2617-0787
E-MAIL : kdk@kdk.co.kr
⊙ A/S처리기간은 5일~4주 정도로, 제품에 따라 상이합니다.
⊙ 무상보증수리 : 제조사의 품질보증 기간에 따라 다릅니다. 무상보증 수리기간은 일반적으로 1년, 3년입니다.
무상보증수리를 위한 왕복 배송료는 대광계측기(주)에서 부담합니다.
단, 무상보증기간일지라도 소모품 교체나 소비자 과실일 경우 비용이 추가될 수 있습니다.
⊙ 유상수리 : 무상보증 기간이 지난 제품에 이상이 생겼을 경우에는 유상수리를 하셔야 합니다.
기본적으로, 수리를 위해 대광계측기(주)로 보내시는 배송료는 고객 부담, 받으시는 배송료는 대광계측기(주)에서 부담합니다.
타사에서 구입한 제품도 대광계측기(주)에서 수리 가능합니다.
상품이 장바구니에 담겼습니다.
바로 확인하시겠습니까?
상품이 찜 리스트에 담겼습니다.
바로 확인하시겠습니까?